PRODUCTS
- Aerial Bundled Cables
- Airport Cables
- Automotive Cables
- Alarm & Audio & Electronic Cables
- Belden Equivalent Cables
- Bus Cables
- Cable Glands
- Cables for Oil Industry
- Coaxial Cables
- Composite Cables
- Control Cables
- Data Cables
- Elevator Cables
- Fiber Optic Cables
- Fire Resisting Cable(Fireflix)
- Fire Retardant Cable(FIRETOX)
- Flame Retardant Cable (FIREGUARD)
- Flexible Cables
- Heat Detection Cables
- High Temperature Cables
- Highway Cables
- Industrial Cables
- Instrumentation Cables
- Marine Cable
- NEK606 Water Blocked Offshore & Marine Cables
- IEC60092 STANDARD Offshore & Marine Cables
- BS 6883&BS7917 STANDARD Offshore & Marine Cables
- UKOOA Offshore & Marine cables
- VG 95218 Navy Cables
- Mining Cables
- Airframe Wire
- Marine, OIL,GAS & Petrochemical Cables
- Power Cables
- Railway Cables
- Robotics
- Rolling Stock Cables
- Rubber & Crane Cables
- Security Cables
- Special Cables
- Spiral Cables
- Telephone Cables
- Thermocouple Cables
- BS 5308 Cable
- PAS 5308 Cable
- BS 5467 Cable
- BS 6724 Cable
- BS 6346 Cable
- BS 7211 Cable
- IEC 60502-1 Cable
HOT PRODUCTS
APPLICATIONS
| Telephone Cables | |||||||||||
|
|||||||||||
A-2Y(L)2Y Outdoor Telecommunication Cable According To DIN VDE 0816 Part 1
Reference Standard: A-2Y(L)2Y according to DIN VDE 0816 Part 1
Application: This cable is used as distribution duct or direct buired telephone cable.
Conductor Material: Solid annealed copper conductor
Insulation Material: PE
Laying-up: Star quads in unit stranding
Wrapping Polyester Tape
Screen Material: Aluminium Foil with copper drain wire
Sheath Material: PE
Sheath Color: Black
Temperature Range: Flexible: -20 ℃ to +50 ℃ fixed installation:- 40℃ to + 70℃
Operating Voltage: 150V to 225V
Electrical Performance:
| Conductor Diameter (mm) | Insulation Resistance of per km at 20 o C Min. (GOhms) | Conductor Resistance per km loop Max. (Ohms) |
| 0.40 | 5 | 300 |
| 0.60 | 5 | 130 |
| 0.80 | 5 | 73.2 |
Size & Dimensions:
A - 2Y(L)2Y ... x 2 x 0,6 STIII BD
| Part No. | No.of pairs | Outerdiameter ( mm ) | Cable Weight ( kg/km ) | Copper Weight (kg/km) |
| CCL-TC-2Y6P0.6 | 6 | 11.5 | 130 | 34 |
| CCL-TC-2Y10P0.6 | 10 | 13.5 | 180 | 57 |
| CCL-TC-2Y20P0.6 | 20 | 16.0 | 275 | 113 |
| CCL-TC-2Y30P0.6 | 30 | 18.0 | 365 | 170 |
| CCL-TC-2Y40P0.6 | 40 | 20.5 | 450 | 226 |
| CCL-TC-2Y50P0.6 | 50 | 21.5 | 535 | 283 |
| CCL-TC-2Y70P0.6 | 70 | 25.5 | 715 | 396 |
| CCL-TC-2Y100P0.6 | 100 | 28.0 | 970 | 565 |
| CCL-TC-2Y150P0.6 | 150 | 32.5 | 1374 | 848 |
| CCL-TC-2Y2006P0.6 | 200 | 37.0 | 1795 | 1131 |
A - 2Y(L)2Y ... x 2 x 0.8 STIII BD
| Part No. | No.of pairs | Outer diameter ( mm ) | Cable Weight ( kg/km ) | Copper Weight (kg/km) |
| CCL-TC-2Y6P0.8 | 6 | 13.0 | 175 | 60 |
| CCL-TC-2Y10P08 | 10 | 15 | 245 | 101 |
| CCL-TC-2Y20P0.8 | 20 | 18.5 | 400 | 201 |
| CCL-TC-2Y30P0.8 | 30 | 21.0 | 550 | 302 |
| CCL-TC-2Y40P0.8 | 40 | 23.0 | 660 | 402 |
| CCL-TC-2Y50P0.8 | 50 | 26.0 | 860 | 503 |
| CCL-TC-2Y70P0.8 | 70 | 29.0 | 1140 | 704 |
| CCL-TC-2Y100P0.8 | 100 | 34.0 | 1580 | 1005 |
| CCL-TC-2Y150P0.8 | 150 | 41.5 | 2265 | 1508 |
| CCL-TC-2Y2006P0.8 | 200 | 47.0 | 3000 | 2011 |